{"id":11531,"date":"2020-10-21T10:34:57","date_gmt":"2020-10-21T09:34:57","guid":{"rendered":"http:\/\/www.on4cn.be\/blog_radio\/?page_id=11531"},"modified":"2020-10-27T07:17:57","modified_gmt":"2020-10-27T06:17:57","slug":"rig-interface","status":"publish","type":"page","link":"http:\/\/www.on4cn.be\/blog_radio\/rig-interface\/","title":{"rendered":"Rig Interface"},"content":{"rendered":"<p style=\"text-align: center;\"><img decoding=\"async\" src=\"http:\/\/www.on4cn.be\/blog_radio\/wp-content\/uploads\/2020\/09\/logo-n3fjp.png\" \/><\/p>\n<p><center><strong><span style=\"color: #ff0000;\"><\/p>\n<h2>Rig Interface Help<\/h2>\n<p><\/span><\/strong><\/center><\/p>\n<p class=\"title\">Aide de l&rsquo;interface de rig<\/p>\n<p class=\"ptext\">Voici les informations essentielles dont vous aurez besoin pour connecter votre interface de plate-forme et de faire fonctionner avec AC Log et mon logiciel de<br \/>\nconcours.<\/p>\n<p class=\"ptext\">Pour commencer avec l&rsquo;interface de rig, vous aurez besoin du mat\u00e9riel d&rsquo;interface n\u00e9cessaire pour connecter votre rig \u00e0 votre PC. De nombreuses plates-formes modernes se connectent d\u00e9sormais directement \u00e0 votre PC<br \/>\navec un simple c\u00e2ble USB. Consultez la section Contr\u00f4le CAT du manuel de votre radio pour plus de d\u00e9tails.<\/p>\n<p class=\"ptext\">Voici une vid\u00e9o que la jeune Faith Hannah, AE4FH a mont\u00e9e, montrant comment interfacer un Icom 7300 avec mon logiciel :<\/p>\n<p><center><iframe loading=\"lazy\" width=\"560\" height=\"315\" src=\"https:\/\/www.youtube.com\/embed\/gVa8T3fK13M\" frameborder=\"0\" allowfullscreen><\/iframe><\/center><br \/>\n\t\t\t\t<\/p>\n<p class=\"ptext\">Pour interfacer votre plate-forme avec mon logiciel, une fois que vous avez le mat\u00e9riel n\u00e9cessaire connect\u00e9 entre votre radio et votre PC, configurez le formulaire d&rsquo;interface de la plate-forme comme suit:<\/p>\n<p>\n\t\t\t\t<center><img decoding=\"async\" src=\"http:\/\/www.on4cn.be\/blog_radio\/wp-content\/uploads\/2020\/09\/RigInterface.jpg\" \/><\/center><\/p>\n<p>1. Pour <b><span style =\"color:maroon;\">S\u00e9lectionnez Rig,<\/span><\/b> s\u00e9lectionnez le rig avec lequel vous interfacez Pour la plupart des plates-formes, il suffit de s\u00e9lectionner la bonne plate-forme pour r\u00e9gler avec pr\u00e9cision votre<br \/>\nvitesse de transmission, parit\u00e9, bits de donn\u00e9es, bits d&rsquo;arr\u00eat et cha\u00eene d&rsquo;interrogation!<\/p>\n<p><b>Utilisateurs Icom uniquement !<\/b> Si vous s\u00e9lectionnez Icom, vous verrez \u00e9galement du texte appara\u00eetre, vous demandant de changer l&rsquo;ID du rig (64 par d\u00e9faut, ce qui se trouve \u00eatre pour le 756 Pro II)<br \/>\n\u00e0 l&rsquo;ID de votre plate-forme (les lignes rouges dans le graphique ci-dessus). Vous devriez \u00eatre en mesure de trouver votre ID de plate-forme dans la section de contr\u00f4le CAT de votre manuel. S&rsquo;il y a un petit h, comme 64h,<br \/>\nignorez-le et entrez simplement le num\u00e9ro \u00e0 deux chiffres. J&rsquo;ai \u00e9galement inclus tous les param\u00e8tres r\u00e9ussis que j&rsquo;ai re\u00e7us d&rsquo;autres utilisateurs ci-dessous, qui incluent l&rsquo;ID du rig.<\/p>\n<p>2. Pour <b><span style =\"color:maroon;\">Port Com,<\/span><\/b> s\u00e9lectionnez le port com auquel votre plate-forme est connect\u00e9e. M\u00eame si un seul port est r\u00e9pertori\u00e9, vous devez toujours cliquer sur<br \/>\nle port pour le s\u00e9lectionner.<\/p>\n<p>3. Pour <b><span style =\"color:maroon;\">Connection Power,<\/span><\/b> s\u00e9lectionnez l&rsquo;option d&rsquo;alimentation, le cas \u00e9ch\u00e9ant, requise par votre interface. La plupart utilisent RTS, certains utilisent DTR et d&rsquo;autres pas<br \/>\nn\u00e9cessitent une option d&rsquo;alimentation du tout.<\/p>\n<p class=\"subtitleleft\" style =\"color:midnightblue; font-size:22px; text-align:center;\"><b>Ready to Go!<\/b><\/p>\n<p>Si vous avez correctement saisi vos param\u00e8tres, vous devriez \u00eatre pr\u00eat \u00e0 activer l&rsquo;interface. Pour essayer &#8230;<\/p>\n<p>4. cliqu\u00e9 <b><span style =\"color:maroon;\"> Sur Test<\/span><\/b> pour commencer \u00e0 interroger votre plate-forme. Si la fr\u00e9quence et le mode apparaissent \u00e0 la fois, vous \u00eates pr\u00eat! Le logiciel suivra votre<br \/>\nfr\u00e9quence, (et bande \u00e0 condition que vous soyez dans les limites d&rsquo;une bande amateur) et mode. De plus, lorsque vous cliquez sur un spot DX depuis le formulaire principal, votre plate-forme s&rsquo;accordera directement \u00e0 cela<br \/>\nla fr\u00e9quence!<\/p>\n<p><\/p>\n<p class=\"subtitleleft\" style =\"color:midnightblue; font-size:22px; text-align:center;\"><b>En cas de difficult\u00e9 &#8211; Ne paniquez pas!<\/b><\/p>\n<p>Si, pour une raison quelconque, vous n&rsquo;obtenez pas de r\u00e9ponse de votre plate-forme, il existe un certain nombre de causes possibles:<\/p>\n<p>Tout d&rsquo;abord, assurez-vous que votre plate-forme est allum\u00e9e et que le mat\u00e9riel d&rsquo;interface de votre plate-forme est correctement connect\u00e9 \u00e0 la fois \u00e0 votre radio ET \u00e0 votre PC.<\/p>\n<p>Assurez-vous que vous avez s\u00e9lectionn\u00e9 le bon port Com.<\/p>\n<p>Assurez-vous que vous avez s\u00e9lectionn\u00e9 la puissance de connexion appropri\u00e9e pour votre interface.<\/p>\n<p>Dans certains cas, certaines plates-formes utilisent des param\u00e8tres autres que les param\u00e8tres par d\u00e9faut. Jetez un \u0153il \u00e0 tous les param\u00e8tres r\u00e9ussis suivants envoy\u00e9s par d&rsquo;autres utilisateurs ci-dessous et corrigez vos param\u00e8tres si n\u00e9cessaire.<\/p>\n<p class=\"subtitleleft\" style =\"color:midnightblue; font-size:22px; text-align:center;\"><b>r\u00e9ussi Rig Settings!<\/b><\/p>\n<p>Ce qui suit sont des param\u00e8tres fonctionnels et r\u00e9ussis que les autres utilisateurs ont eu la gentillesse d&rsquo;envoyer. Notez que l&rsquo;option Port Com et alimentation d\u00e9pendra de votre PC et de votre interface, donc<br \/>\nces deux param\u00e8tres peuvent \u00eatre diff\u00e9rents des param\u00e8tres r\u00e9pertori\u00e9s ci-dessous.<\/p>\n<p>Si vous essayez ces param\u00e8tres pour votre plate-forme sans succ\u00e8s, quelque chose de sp\u00e9cifique \u00e0 la plate-forme ou au mat\u00e9riel d&rsquo;interface est probablement en jeu. Puisque je n&rsquo;ai qu&rsquo;un Kenwood TS 440s un Icom 756 Pro II<br \/>\net Icom 7610 ici, je ne serai pas en mesure de fournir une assistance suppl\u00e9mentaire pour toute autre plate-forme ou interface. Si vous ne parvenez pas \u00e0 d\u00e9marrer votre plate-forme apr\u00e8s avoir essay\u00e9 les param\u00e8tres ci-dessous, veuillez<br \/>\nn&rsquo;h\u00e9sitez pas \u00e0 rechercher les archives des messages sur le<br \/>\n<a href=\"https:\/\/www.n3fjp.com\/yahoogroups.html\">Users group<\/a> ou postez une question l\u00e0-bas. Il est probable que quelqu&rsquo;un avec une plate-forme et une interface similaires puisse vous aider.<\/p>\n<p>If you have settings for a rig not listed below, I would be <b>very grateful<\/b> if you would send them along, by clicking the Copy Data to Clipboard button while polling your rig and pasting the contents into an e-mail!<\/p>\n<p class=\"ptext\">\n<p>\t\t\t\t<b>Elecraft K2<\/b><br \/>\n\t\t\t\tRig Name = Elecraft<br \/>\nRead Frequency Command = FA;<br \/>\nRead Mode Command = MD;<br \/>\nConvert To Hex = False<br \/>\nBaud Rate = 4800<br \/>\nParity = None<br \/>\nStop Bits = 2<br \/>\nData Bits = 8<br \/>\nPower Option = RTS<\/p>\n<p><b>Elecraft K3<\/b><br \/>\nRig Name = Elecraft<br \/>\nRead Frequency Command = FA;<br \/>\nRead Mode Command = MD;<br \/>\nConvert To Hex = False<br \/>\nBaud Rate = 38400<br \/>\nParity = None<br \/>\nStop Bits = 2<br \/>\nData Bits = 8<br \/>\nPower Option = RTS<\/p>\n<p><b>Elecraft K3S<\/b><br \/>\nRig Name = Elecraft<br \/>\nRead Frequency Command = FA;<br \/>\nRead Mode Command = MD;<br \/>\nConvert To Hex = False<br \/>\nBaud Rate = 38400<br \/>\nParity = None<br \/>\nStop Bits = 1<br \/>\nData Bits = 8<br \/>\nPower Option = RTS<\/p>\n<p><b>Elecraft KX2<\/b><br \/>\nRig Name = Elecraft <br \/>\nRead Frequency Command = FA <br \/>\nRead Mode Command = MD <br \/>\nConvert to Hex = False <br \/>\nBaud Rate= 38.4 <br \/>\nParity = None <br \/>\nStop Bits= 2 <br \/>\nData Bits = 8 <br \/>\nPower Option = RTS<\/p>\n<p><b>Elecraft KX3<\/b><br \/>\nRig Name = Elecraft <br \/>\nRead Frequency Command = FA <br \/>\nRead Mode Command = MD <br \/>\nConvert to Hex = False <br \/>\nBaud Rate= 4.8 <br \/>\nParity = None <br \/>\nStop Bits= 2 <br \/>\nData Bits = 8 <br \/>\nPower Option = RTS<\/p>\n<p><b>FLdigi<\/b><br \/>\nRig Name = Kenwood<br \/>\nRead Frequency Command = FA;<br \/>\nRead Mode Command = MD;<br \/>\nConvert To Hex = False<br \/>\nBaud Rate = 9600<br \/>\nParity = None<br \/>\nStop Bits = 2<br \/>\nData Bits = 8<br \/>\nPower Option = RTS<\/p>\n<p><b>Flex Radio (via API)<\/b><br \/>\nRig Name = Flex API<\/p>\n<p>Note, no other settings are required with the Flex API option.  With this option, my software will track the active slice.<\/p>\n<p><b>Flex Radio<\/b><br \/>\nRig Name = FlexRadio<br \/>\nRead Frequency Command = FA;<br \/>\nRead Mode Command = MD;<br \/>\nConvert To Hex = False<br \/>\nBaud Rate = 4800<br \/>\nParity = None<br \/>\nStop Bits = 2<br \/>\nData Bits = 8<br \/>\nPower Option = None<\/p>\n<p><b>Icom 703<\/b><br \/>\nRig Name = Icom<br \/>\nRead Frequency Command = FE FE 68 E0 03 FD<br \/>\nRead Mode Command = FE FE 68 E0 04 FD<br \/>\nConvert To Hex = True<br \/>\nBaud Rate = 19200<br \/>\nParity = None<br \/>\nStop Bits = 1<br \/>\nData Bits = 8<br \/>\nPower Option = None<\/p>\n<p><b>Icom 705<\/b><br \/>\nRead Frequency Command = FE FE A4 E0 03 FD<br \/>\nRead Mode Command = FE FE A4 E0 04 FD<br \/>\nConvert To Hex = True<br \/>\nBaud Rate = 56000<br \/>\nParity = None<br \/>\nStop Bits = 1<br \/>\nData Bits = 8<br \/>\nPower Option = None<\/p>\n<p><b>Icom 706<\/b><br \/>\nRig Name = Icom<br \/>\nRead Frequency Command = FE FE 48 E0 03 FD<br \/>\nRead Mode Command = FE FE 48 E0 04 FD<br \/>\nConvert To Hex = True<br \/>\nBaud Rate = 1200<br \/>\nParity = None<br \/>\nStop Bits = 1<br \/>\nData Bits = 8<br \/>\nPower Option = RTS<\/p>\n<p><b>Icom 706 MK II<\/b><br \/>\nRig Name = Icom<br \/>\nRead Frequency Command = FE FE 4E F0 03 FD<br \/>\nRead Mode Command = FE FE 4E E0 04 FD<br \/>\nConvert To Hex = True<br \/>\nBaud Rate = 19200<br \/>\nParity = None<br \/>\nStop Bits = 1<br \/>\nData Bits = 8<br \/>\nPower Option = RTS<\/p>\n<p><b>Icom 706 MK II G<\/b><br \/>\nRig Name = Icom<br \/>\nRead Frequency Command = FE FE 58 F0 03 FD<br \/>\nRead Mode Command = FE FE 58 E0 04 FD<br \/>\nConvert To Hex = True<br \/>\nBaud Rate = 9600<br \/>\nParity = None<br \/>\nStop Bits = 1<br \/>\nData Bits = 8<br \/>\nPower Option = RTS<\/p>\n<p><b>Icom 718<\/b><br \/>\nRig Name = Icom<br \/>\nRead Frequency Command = FE FE 5E E0 03 FD<br \/>\nRead Mode Command = FE FE 5E E0 04 FD<br \/>\nConvert To Hex = True<br \/>\nBaud Rate = 9600<br \/>\nParity = None<br \/>\nStop Bits = 1<br \/>\nData Bits = 8<br \/>\nPower Option = RTS<\/p>\n<p><b>Icom 728<\/b><br \/>\nRig Name = Icom<br \/>\nRead Frequency Command = FE FE 5E E0 03 FD (another user said 38 was the correct rig ID)<br \/>\nRead Mode Command = FE FE 5E E0 04 FD<br \/>\nConvert To Hex = True<br \/>\nBaud Rate = 19200<br \/>\nParity = None<br \/>\nStop Bits = 1<br \/>\nData Bits = 8<br \/>\nPower Option = DTR<\/p>\n<p><b>Icom 735<\/b><br \/>\nRig Name = Icom 735<br \/>\nRead Frequency Command = FE FE 04 E0 03 FD<br \/>\nRead Mode Command = FE FE 04 E0 04 FD<br \/>\nConvert To Hex = True<br \/>\nBaud Rate = 9600<br \/>\nParity = None<br \/>\nStop Bits = 1<br \/>\nData Bits = 8<br \/>\nPower Option = None<\/p>\n<p>Note &#8211; Icom 735 users report it is particularly important that you use the 9600 baud rate with this radio.  You may have to adjust the radio&rsquo;s baud rate by manually removing the cover and changing a jumper in the 735.<\/p>\n<p><b>Icom 737<\/b><br \/>\nRig Name = Icom<br \/>\nRead Frequency Command = FE FE 03 E0 03 FD<br \/>\nRead Mode Command = FE FE 03 E0 04 FD<br \/>\nConvert To Hex = True<br \/>\nBaud Rate = 9600<br \/>\nParity = None<br \/>\nStop Bits = 1<br \/>\nData Bits = 8<br \/>\nPower Option = RTS<\/p>\n<p><b>Icom 738<\/b><br \/>\nRig Name = Icom<br \/>\nRead Frequency Command = FE FE 44 E0 03 FD<br \/>\nRead Mode Command = FE FE 44 E0 04 FD<br \/>\nConvert To Hex = True<br \/>\nBaud Rate = 9600<br \/>\nParity = None<br \/>\nStop Bits = 1<br \/>\nData Bits = 8<br \/>\nPower Option = None<\/p>\n<p><b>Icom 746 Pro<\/b><br \/>\nRig Name = Icom<br \/>\nRead Frequency Command = FE FE 66 E0 03 FD<br \/>\nRead Mode Command = FE FE 66 E0 04 FD<br \/>\nConvert To Hex = True<br \/>\nBaud Rate = 19200<br \/>\nParity = None<br \/>\nStop Bits = 1<br \/>\nData Bits = 8<br \/>\nPower Option = DTR<\/p>\n<p><b>Icom 751A<\/b><br \/>\nRig Name = Icom<br \/>\nRead Frequency Command = FE FE 1C E0 03 FD<br \/>\nRead Mode Command = FE FE 1C E0 04 FD<br \/>\nConvert To Hex = True<br \/>\nBaud Rate = 9600<br \/>\nParity = None<br \/>\nStop Bits = 1<br \/>\nData Bits = 8<br \/>\nPower Option = RTS<\/p>\n<p><b>Icom 756 Pro<\/b><br \/>\nRig Name = Icom<br \/>\nRead Frequency Command = FE FE 5C E0 03 FD<br \/>\nRead Mode Command = FE FE 5C E0 04 FD<br \/>\nConvert To Hex = True<br \/>\nBaud Rate = 9600 (Note &#8211; one user reported success with baud rate of 1200)<br \/>\nParity = None<br \/>\nStop Bits = 1<br \/>\nData Bits = 8<br \/>\nPower Option = RTS<\/p>\n<p><b>Icom 756 Pro II<\/b><br \/>\nRig Name = Icom<br \/>\nRead Frequency Command = FE FE 64 E0 03 FD<br \/>\nRead Mode Command = FE FE 64 E0 04 FD<br \/>\nConvert To Hex = True<br \/>\nBaud Rate = 1200<br \/>\nParity = None<br \/>\nStop Bits = 1<br \/>\nData Bits = 8<br \/>\nPower Option = RTS<\/p>\n<p><b>Icom 756 Pro III<\/b><br \/>\nRig Name = Icom<br \/>\nRead Frequency Command = FE FE 6E E0 03 FD<br \/>\nRead Mode Command = FE FE 6E E0 04 FD<br \/>\nConvert To Hex = True<br \/>\nBaud Rate = 19200<br \/>\nParity = None<br \/>\nStop Bits = 1<br \/>\nData Bits = 8<br \/>\nPower Option = None<\/p>\n<p><b>Icom 765<\/b><br \/>\nRig Name = Icom <br \/>\nRead Frequency Command = FE FE 2C E0 03 FD <br \/>\nRead Mode Command = FE FE 2C E0 04 FD <br \/>\nConvert To Hex = True <br \/>\nBaud Rate = 1200 <br \/>\nParity = None <br \/>\nStop Bits = 1 <br \/>\nData Bits = 8 <br \/>\nPower Option = None <\/p>\n<p><b>Icom 775<\/b><br \/>\nRig Name = Icom<br \/>\nRead Frequency Command = FE FE 46 E0 03 FD<br \/>\nRead Mode Command = FE FE 46 E0 04 FD<br \/>\nConvert To Hex = True<br \/>\nBaud Rate = 19200<br \/>\nParity = None<br \/>\nStop Bits = 1<br \/>\nData Bits = 8<br \/>\nPower Option = None<\/p>\n<p><b>Icom 821<\/b><br \/>\nRig Name = Icom<br \/>\nRead Frequency Command = FE FE 4C E0 03 FD<br \/>\nRead Mode Command = FE FE 4C E0 04 FD<br \/>\nConvert To Hex = True<br \/>\nBaud Rate = 19200<br \/>\nParity = None<br \/>\nStop Bits = 1<br \/>\nData Bits = 8<br \/>\nPower Option = RTS<\/p>\n<p><b>Icom 7000<\/b><br \/>\nRig Name = Icom<br \/>\nRead Frequency Command = FE FE 70 E0 03 FD<br \/>\nRead Mode Command = FE FE 70 E0 04 FD<br \/>\nConvert To Hex = True<br \/>\nBaud Rate = 19200<br \/>\nParity = None<br \/>\nStop Bits = 1<br \/>\nData Bits = 8<br \/>\nPower Option = DTR<\/p>\n<p><b>Icom 7100<\/b><br \/>\nRig Name = Icom<br \/>\nRead Frequency Command = FE FE 88 E0 03 FD<br \/>\nRead Mode Command = FE FE 88 E0 04 FD<br \/>\nConvert To Hex = True<br \/>\nBaud Rate = 19200<br \/>\nParity = None<br \/>\nStop Bits = 1<br \/>\nData Bits = 8<br \/>\nPower Option = RTS<\/p>\n<p><b>Icom 7200<\/b><br \/>\nRig Name = Icom<br \/>\nRead Frequency Command = FE FE 76 E0 03 FD<br \/>\nRead Mode Command = FE FE 76 E0 04 FD<br \/>\nConvert To Hex = True<br \/>\nBaud Rate = 19200<br \/>\nParity = None<br \/>\nStop Bits = 1<br \/>\nData Bits = 8<br \/>\nPower Option = None<\/p>\n<p><b>Icom 7300<\/b><br \/>\nRig Name = Icom<br \/>\nRead Frequency Command = FE FE 94 E0 03 FD<br \/>\nRead Mode Command = FE FE 94 E0 04 FD<br \/>\nConvert To Hex = True<br \/>\nBaud Rate = 9600 (one user reported 56000, another reported 4800, but most reports have been 9600.)<br \/>\nParity = None<br \/>\nStop Bits = 1<br \/>\nData Bits = 8<br \/>\nPower Option = None<br \/>\nRob, KD9INB reports:  \u00ab\u00a0Had to turn the connection power to \u00ab\u00a0Off\u00a0\u00bb in the software setting AND also in the rig,  and also had to set the CI-V port in the rig from\u00a0\u00bbUnlinked\u00a0\u00bb to \u00ab\u00a0Linked\u00a0\u00bb.  Made sure the baud rate setting in the rig and software matched and viola!  Works like a charm now.\u00a0\u00bb<\/p>\n<p><b>Icom 7410<\/b><br \/>\nRig Name = Icom<br \/>\nRead Frequency Command = FE FE 80 E0 03 FD<br \/>\nRead Mode Command = FE FE 80 E0 04 FD<br \/>\nNote &#8211; another user wrote that his 7410 used 3F instead of 80<br \/>\nConvert To Hex = True<br \/>\nBaud Rate = 9600<br \/>\nParity = None<br \/>\nStop Bits = 1<br \/>\nData Bits = 8<br \/>\nPower Option = RTS<\/p>\n<p><b>Icom 7600<\/b><br \/>\nRig Name = Icom<br \/>\nRead Frequency Command = FE FE 7A E0 03 FD<br \/>\nRead Mode Command = FE FE 7A E0 04 FD<br \/>\nConvert To Hex = True<br \/>\nBaud Rate = 9600<br \/>\nParity = None<br \/>\nStop Bits = 1<br \/>\nData Bits = 8<br \/>\nPower Option = None<\/p>\n<p><b>Icom 7610<\/b><br \/>\nRig Name = Icom2<br \/>\n<!--Note - if you choose the Icom option instead of Icom2, you must set your IC-7610 menu system to echo received CI-V commands.  You'll find the instructions on page 8-7 of your manual (bottom left), or at about the 3:40 mark of this video, courtesy Jack NK7J:\n\n\n\n\n<p class=\"ptextcenter\"><iframe loading=\"lazy\" width=\"560\" height=\"315\" src=\"https:\/\/www.youtube.com\/embed\/K_9GpY2jyO0?start=220\" frameborder=\"0\" gesture=\"media\" allow=\"encrypted-media\" allowfullscreen><\/iframe><\/p>\n\n--><br \/>\nRead Frequency Command = FE FE 98 E0 03 FD<br \/>\nRead Mode Command = FE FE 98 E0 04 FD<br \/>\nConvert To Hex = True<br \/>\nBaud Rate = 38400<br \/>\nParity = None<br \/>\nStop Bits = 1<br \/>\nData Bits = 8<br \/>\nPower Option = None<\/p>\n<p><b>Icom 7700<\/b><br \/>\nRead Frequency Command = FE FE 74 E0 03 FD<br \/>\nRead Mode Command = FE FE 74 E0 04 FD<br \/>\nConvert To Hex = True<br \/>\nBaud Rate = 9600<br \/>\nParity = None<br \/>\nStop Bits = 1<br \/>\nData Bits = 8<br \/>\nPower Option = RTS<\/p>\n<p><b>Icom 7800<\/b><br \/>\nRig Name = Icom<br \/>\nRead Frequency Command = FE FE 6A E0 03 FD<br \/>\nRead Mode Command = FE FE 6A E0 04 FD<br \/>\nConvert To Hex = True<br \/>\nBaud Rate = 9600<br \/>\nParity = None<br \/>\nStop Bits = 1<br \/>\nData Bits = 8<br \/>\nPower Option = RTS<\/p>\n<p><b>Icom 7851<\/b><br \/>\nRig Name = Icom<br \/>\nRead Frequency Command = FE FE 8E E0 03 FD<br \/>\nRead Mode Command = FE FE 8E E0 04 FD<br \/>\nConvert To Hex = True<br \/>\nBaud Rate = 9600 <br \/>\nParity = None<br \/>\nStop Bits = 1<br \/>\nData Bits = 8<br \/>\nPower Option = RTS<\/p>\n<p>David, WB4OZM notes:  When one wants to use the USB cable instead of the 3.5mm plug in the remote outlet, I need the CV-V USB Echo Back in the \u00ab\u00a0ON\u00a0\u00bb position. After that all works very well! (Selecting Icom2 should remedy that.)<\/p>\n<p><b>Icom 9100<\/b><br \/>\nRig Name = Icom<br \/>\nRead Frequency Command = FE FE 7C E0 03 FD<br \/>\nRead Mode Command = FE FE 7C E0 04 FD<br \/>\nConvert To Hex = True<br \/>\nBaud Rate = 9600 (another user reported 19.2 worked for him)<br \/>\nParity = None<br \/>\nStop Bits = 1<br \/>\nData Bits = 8<br \/>\nPower Option = RTS<\/p>\n<p><b>Icom 9700<\/b><br \/>\nRig Name = Icom2<br \/>\nRead Frequency Command = FE FE A2 E0 03 FD<br \/>\nRead Mode Command = FE FE A2 E0 04 FD<br \/>\nConvert To Hex = True<br \/>\nBaud Rate = 19200<br \/>\nParity = None<br \/>\nStop Bits = 1<br \/>\nData Bits = 8<br \/>\nPower Option = RTS<\/p>\n<p><b>Note &#8211; Kenwood rigs have two options<\/b> and most will work with either selection, though I recommend Kenwood2.  The settings listed below are the ones users just happened to send in.  The first setting, Kenwood, always reads the VFO specified (FA; reads VFO A and FB; reads VFO B).  Kenwood2 always reads the <b>active<\/b> VFO.  Kenwood2 also sometimes returns a mode when the first setting does not.<\/p>\n<p><b>Kenwood TS 440s<\/b><br \/>\nRig Name = Kenwood2<br \/>\nRead Frequency Command = IF;<br \/>\nRead Mode Command = <br \/>\nConvert To Hex = False<br \/>\nBaud Rate = 4800<br \/>\nParity = None<br \/>\nStop Bits = 2<br \/>\nData Bits = 8<br \/>\nPower Option = RTS<\/p>\n<p><b>Kenwood TS 480HX<\/b><br \/>\nRig Name = Kenwood<br \/>\nRead Frequency Command = FA;<br \/>\nRead Mode Command = MD;<br \/>\nConvert To Hex = False<br \/>\nBaud Rate = 9600<br \/>\nParity = None<br \/>\nStop Bits = 1<br \/>\nData Bits = 8<br \/>\nPower Option = RTS<\/p>\n<p><b>Kenwood TS 570<\/b><br \/>\nRig Name = Kenwood2<br \/>\nRead Frequency Command = IF;<br \/>\nRead Mode Command =<br \/>\nConvert To Hex = False<br \/>\nBaud Rate = 9600<br \/>\nParity = None<br \/>\nStop Bits = 1<br \/>\nData Bits = 8<br \/>\nPower Option = RTS<\/p>\n<p><b>Kenwood TS 590<\/b><br \/>\nRig Name = Kenwood2<br \/>\nRead Frequency Command = IF;<br \/>\nRead Mode Command = <br \/>\nConvert To Hex = False<br \/>\nBaud Rate = 9600 (some users report 115200)<br \/>\nParity = None<br \/>\nStop Bits = 1<br \/>\nData Bits = 8<br \/>\nPower Option = RTS<br \/>\nPlease note that for the Kenwoood 590, users have reported it is necessary to change the rig&rsquo;s default baud rate as one user <a href=\"https:\/\/groups.yahoo.com\/neo\/groups\/N3FJP_Software_Users\/conversations\/messages\/22133\" target=\"blank\" rel=\"noopener noreferrer\">detailed here<\/a> on the Users group.  In short, he writes \u00ab\u00a0I now set everything to 38.4 \u2013 the 2 menu settings that I didn\u2019t know existed (61 and 62) as well as the device manager for the bridge and the software, and waalaa!  It works like advertised!\u00a0\u00bb  That said, another 590 user reported that his 590 worked fine at 9600 baud.  Also, you can enter any baud rate you like by clicking the Other button.<\/p>\n<p><b>Kenwood TS 870<\/b><br \/>\nRead Frequency Command = FA;<br \/>\nRead Mode Command = MD;<br \/>\nConvert To Hex = False<br \/>\nBaud Rate = 9600<br \/>\nParity = None<br \/>\nStop Bits = 1<br \/>\nData Bits = 8<br \/>\nPower Option = RTS<\/p>\n<p><b>Kenwood TS 990<\/b><br \/>\nRig Name = Kenwood2<br \/>\nRead Frequency Command = IF;<br \/>\nRead Mode Command = <br \/>\nConvert To Hex = False<br \/>\nBaud Rate = 115,200 (Click Other Button)<br \/>\nParity = None<br \/>\nStop Bits = 1<br \/>\nData Bits = 8<br \/>\nPower Option = RTS<\/p>\n<p><b>Kenwood TS 2000<\/b><br \/>\nRig Name = Kenwood2<br \/>\nRead Frequency Command = IF;<br \/>\nRead Mode Command = <br \/>\nConvert To Hex = False <br \/>\nBaud Rate = 9600 <br \/>\nParity = None <br \/>\nStop Bits = 2 <br \/>\nData Bits = 8 <br \/>\nPower Option = RTS <\/p>\n<p><b>Ten Tec Jupiter<\/b><br \/>\nRig Name = Ten Tec Fnt Pnl<br \/>\nRead Frequency Command = 3F 41 0D<br \/>\nRead Mode Command = 3F 4D 0D<br \/>\nConvert To Hex = True<br \/>\nBaud Rate = 56000  (Another user reported 57600)<br \/>\nParity = None<br \/>\nStop Bits = 1<br \/>\nData Bits = 8<br \/>\nPower Option = RTS  (Another user reported Both)<\/p>\n<p><b>Ten Tec Omni VI<\/b><br \/>\nRig Name = Ten Tec Omni VI<br \/>\nRead Frequency Command = FE FE 04 E0 03 FD<br \/>\nRead Mode Command = FE FE 04 E0 04 FD<br \/>\nConvert To Hex = True<br \/>\nBaud Rate = 19200<br \/>\nParity = None<br \/>\nStop Bits = 1<br \/>\nData Bits = 8<br \/>\nPower Option = RTS<\/p>\n<p><b>Ten Tec Omni VII<\/b><br \/>\nRig Name = Ten Tec Omni VII<br \/>\nRead Frequency Command = ?A<br \/>\nRead Mode Command = ?M<br \/>\nConvert To Hex = True<br \/>\nBaud Rate = 56000<br \/>\nParity = None<br \/>\nStop Bits = 1<br \/>\nData Bits = 8<br \/>\nPower Option = RTS<\/p>\n<p><b>Ten Tec Orion I<\/b><br \/>\nRig Name = Ten Tec Orion<br \/>\nRead Frequency Command = ?AF<br \/>\nRead Mode Command = ?RMM<br \/>\nConvert To Hex = False<br \/>\nBaud Rate = 56000<br \/>\nParity = None<br \/>\nStop Bits = 1<br \/>\nData Bits = 8<br \/>\nPower Option = RTS<\/p>\n<p><b>Ten Tec Orion II<\/b><br \/>\nRig Name = Ten Tec Orion<br \/>\nRead Frequency Command = ?AF<br \/>\nRead Mode Command = ?RMM<br \/>\nConvert To Hex = False<br \/>\nBaud Rate = 56000<br \/>\nParity = None<br \/>\nStop Bits = 1<br \/>\nData Bits = 8<br \/>\nPower Option = RTS<\/p>\n<p><b>Xiegu X5105<\/b><br \/>\nRig Name = Icom<br \/>\nRead Frequency Command = FE FE 70 E0 03 FD<br \/>\nRead Mode Command = FE FE 70 E0 04 FD<br \/>\nConvert To Hex = True<br \/>\nBaud Rate = 19200<br \/>\nParity = None<br \/>\nStop Bits = 1<br \/>\nData Bits = 8<br \/>\nPower Option = DTR<\/p>\n<p><b>Yaesu 100D<\/b><br \/>\nRig Name = Yaesu 100D<br \/>\nRead Frequency Command = 00 00 00 02 10<br \/>\nRead Mode Command = <br \/>\nConvert To Hex = True<br \/>\nBaud Rate = 19200<br \/>\nParity = None<br \/>\nStop Bits = 2<br \/>\nData Bits = 8<br \/>\nPower Option = None<\/p>\n<p><b>Yaesu 100MP<\/b><br \/>\nRig Name = Yaesu 991 (That&rsquo;s correct, please use the 991 selection)<br \/>\nRead Frequency Command = FA;<br \/>\nRead Mode Command = MD0;<br \/>\nConvert To Hex = False<br \/>\nBaud Rate = 4800<br \/>\nParity = None<br \/>\nStop Bits = 2<br \/>\nData Bits = 8<br \/>\nPower Option = Both<\/p>\n<p><b>Yaesu 101D<\/b><br \/>\nRig Name =  Yaesu Newer 2<br \/>\nRead Frequency Command = FA;<br \/>\nRead Mode Command = MD0;<br \/>\nConvert To Hex = False<br \/>\nBaud Rate = 9600<br \/>\nParity = None<br \/>\nStop Bits = 2<br \/>\nData Bits = 8<br \/>\nPower Option = RTS<\/p>\n<p><b>Yaesu 101MP<\/b><br \/>\nRig Name =  Yaesu Newer 2<br \/>\nRead Frequency Command = FA;<br \/>\nRead Mode Command = MD0;<br \/>\nConvert To Hex = False<br \/>\nBaud Rate = 38400<br \/>\nParity = None<br \/>\nStop Bits = 2<br \/>\nData Bits = 8<br \/>\nPower Option = RTS<\/p>\n<p><b>Yaesu 450D<\/b><br \/>\nRig Name = Yaesu &#8211; Newer<br \/>\nRead Frequency Command = FA;<br \/>\nRead Mode Command = MD0;<br \/>\nConvert To Hex = False<br \/>\nBaud Rate = 38400<br \/>\nParity = None<br \/>\nStop Bits = 2<br \/>\nData Bits = 8<br \/>\nPower Option = RTS<\/p>\n<p><b>Yaesu 817<\/b><br \/>\nRig Name = Yaesu &#8211; Older<br \/>\nRead Frequency Command = 00 00 00 00 03<br \/>\nRead Mode Command = <br \/>\nConvert To Hex = True<br \/>\nBaud Rate = 38400<br \/>\nParity = None<br \/>\nStop Bits = 2<br \/>\nData Bits = 8<br \/>\nPower Option = RTS<\/p>\n<p><b>Yaesu 847<\/b><\/p>\n<p>Note &#8211; Some, but not all Yaesu 847 users were having trouble interfacing with the new, C#.NET versions of my software. This problem has been corrected in rig interface verion 1.3 and later by sending a command to start cat control when the port is opened if Yaesu &#8211; Older is selected.  Your 847 must first be turned on before starting rig interface with the software.<\/p>\n<p>Rig Name = Yaesu &#8211; Older<br \/>\nRead Frequency Command = 00 00 00 00 03<br \/>\nRead Mode Command = <br \/>\nConvert To Hex = True<br \/>\nBaud Rate = 9600<br \/>\nParity = None<br \/>\nStop Bits = 2<br \/>\nData Bits = 8<br \/>\nPower Option = RTS<\/p>\n<p><b>Yaesu 857<\/b><br \/>\nRig Name = Yaesu &#8211; Older<br \/>\nRead Frequency Command = 00 00 00 00 03<br \/>\nRead Mode Command = <br \/>\nConvert To Hex = True<br \/>\nBaud Rate = 4800<br \/>\nParity = None<br \/>\nStop Bits = 2<br \/>\nData Bits = 8<br \/>\nPower Option = RTS<\/p>\n<p><b>Yaesu 890<\/b><br \/>\nRig Name = Yaesu 890<br \/>\nRead Frequency Command = 00 00 00 02 10<br \/>\nRead Mode Command = <br \/>\nConvert To Hex = True<br \/>\nBaud Rate = 4800<br \/>\nParity = None<br \/>\nStop Bits = 2<br \/>\nData Bits = 8<br \/>\nPower Option = RTS<\/p>\n<p><b>Yaesu 891<\/b><br \/>\nRig Name = Yaesu 891<br \/>\nRead Frequency Command = FA;<br \/>\nRead Mode Command = MD0;<br \/>\nConvert To Hex = False<br \/>\nBaud Rate = 9600<br \/>\nParity = None<br \/>\nStop Bits = 2 (some users report 1)<br \/>\nData Bits = 8<br \/>\nPower Option = RTS<\/p>\n<p>Additional SSB \/ CW memory CAT commands courtesy Ray, W8RD:  <a href=\"http:\/\/w8rd.net\/FT-891\/ACLog%20extended%20rig%20control.pdf\" target=\"blank\" rel=\"noopener noreferrer\">http:\/\/w8rd.net\/FT-891\/ACLog%20extended%20rig%20control.pdf<\/a><\/p>\n<p><b>Yaesu 897<\/b><br \/>\nRig Name = Yaesu &#8211; Older<br \/>\nRead Frequency Command = 00 00 00 00 03<br \/>\nRead Mode Command = <br \/>\nConvert To Hex = True<br \/>\nBaud Rate = 4800<br \/>\nParity = None<br \/>\nStop Bits = 2<br \/>\nData Bits = 8<br \/>\nPower Option = RTS<\/p>\n<p><b>Yaesu 900<\/b><br \/>\nRig Name = Yaesu 900<br \/>\nRead Frequency Command = 00 00 00 02 10<br \/>\nRead Mode Command = <br \/>\nConvert To Hex = True<br \/>\nBaud Rate = 4800<br \/>\nParity = None<br \/>\nStop Bits = 1<br \/>\nData Bits = 8<br \/>\nPower Option = RTS<\/p>\n<p><b>Yaesu 920<\/b><br \/>\nRig Name = Yaesu 920<br \/>\nRead Frequency Command = 00 00 00 02 10<br \/>\nRead Mode Command = <br \/>\nConvert To Hex = True<br \/>\nBaud Rate = 4800<br \/>\nParity = None<br \/>\nStop Bits = 2<br \/>\nData Bits = 8<br \/>\nPower Option = RTS<\/p>\n<p><b>Yaesu 950<\/b><br \/>\nRig Name = Yaesu &#8211; Newer<br \/>\nRead Frequency Command = FA;<br \/>\nRead Mode Command = MD0;<br \/>\nConvert To Hex = False<br \/>\nBaud Rate = 4800<br \/>\nParity = None<br \/>\nStop Bits = 2<br \/>\nData Bits = 8<br \/>\nPower Option = RTS<\/p>\n<p><b>Yaesu 991<\/b><br \/>\nRig Name = Yaesu Newer 2<br \/>\nRead Frequency Command = FA;<br \/>\nRead Mode Command = MD0;<br \/>\nConvert To Hex = False<br \/>\nBaud Rate = 9600<br \/>\nParity = None<br \/>\nStop Bits = 2<br \/>\nData Bits = 8<br \/>\nPower Option = RTS<\/p>\n<p><b>Yaesu 1000<\/b><br \/>\nRig Name = Yaesu 1000<br \/>\nRead Frequency Command = 00 00 00 02 10<br \/>\nRead Mode Command = <br \/>\nConvert To Hex = True<br \/>\nBaud Rate = 4800<br \/>\nParity = None<br \/>\nStop Bits = 2<br \/>\nData Bits = 8<br \/>\nPower Option = RTS<\/p>\n<p><b>Yaesu 1000 D<\/b><br \/>\nRig Name = Yaesu 1000 D<br \/>\nRead Frequency Command = 00 00 00 02 10<br \/>\nRead Mode Command =<br \/>\nConvert To Hex = True<br \/>\nBaud Rate = 4800<br \/>\nParity = None<br \/>\nStop Bits = 2<br \/>\nData Bits = 8<br \/>\nPower Option = RTS<\/p>\n<p><b>Yaesu 1000 MP<\/b><br \/>\nRig Name = Yaesu 1000<br \/>\nRead Frequency Command = 00 00 00 02 10<br \/>\nRead Mode Command =<br \/>\nConvert To Hex = True<br \/>\nBaud Rate = 4800<br \/>\nParity = None<br \/>\nStop Bits = 2<br \/>\nData Bits = 8<br \/>\nPower Option = RTS<\/p>\n<p><b>Yaesu 1200<\/b><br \/>\nRig Name = Yaesu &#8211; Newer<br \/>\nRead Frequency Command = FA;<br \/>\nRead Mode Command = MD0;<br \/>\nConvert To Hex = False<br \/>\nBaud Rate = 38400 (some users report 4800 also works)<br \/>\nParity = None<br \/>\nStop Bits = 2<br \/>\nData Bits = 8<br \/>\nPower Option = RTS<\/p>\n<p><b>Yaesu 2000<\/b><br \/>\nRig Name = Yaesu &#8211; Newer<br \/>\nRead Frequency Command = FA;<br \/>\nRead Mode Command = MD0;<br \/>\nConvert To Hex = False<br \/>\nBaud Rate = 38400<br \/>\nParity = None<br \/>\nStop Bits = 2<br \/>\nData Bits = 8<br \/>\nPower Option = RTS<\/p>\n<p><b>Yaesu 3000<\/b><br \/>\nRig Name = Yaesu &#8211; Newer <br \/>\nRead Frequency Command = FA; <br \/>\nRead Mode Command = MD0; <br \/>\nConvert To Hex = False <br \/>\nBaud Rate = 38400 <br \/>\nParity = None <br \/>\nStop Bits = 2 <br \/>\nData Bits = 8 <br \/>\nPower Option = RTS <\/p>\n<p>A user reported the following codes can be used in the phone F key set up form for firing the Yaesu 3000 rig voice memories:<br \/>\nRI:PB01;<br \/>\nRI:PB02;<br \/>\nRI:PB03;<br \/>\nRI:PB04;<br \/>\nRI:PB05;<\/p>\n<p><b>Yaesu 5000<\/b><br \/>\nRig Name = Yaesu &#8211; Newer<br \/>\nRead Frequency Command = FA;<br \/>\nRead Mode Command = MD0;<br \/>\nConvert To Hex = False<br \/>\nBaud Rate = 38400<br \/>\nParity = None<br \/>\nStop Bits = 2<br \/>\nData Bits = 8<br \/>\nPower Option = RTS<\/p>\n<p><b>Yaesu 9000<\/b><br \/>\nRig Name = Yaesu &#8211; Newer<br \/>\nRead Frequency Command = FA;<br \/>\nRead Mode Command = MD0;<br \/>\nConvert To Hex = False<br \/>\nBaud Rate = 19200<br \/>\nParity = None<br \/>\nStop Bits = 2<br \/>\nData Bits = 8<br \/>\nPower Option = RTS<\/p>\n<p><b>Yaesu Mark V<\/b><br \/>\nRig Name = Yaesu 1000<br \/>\nRead Frequency Command = 00 00 00 02 10<br \/>\nRead Mode Command = <br \/>\nConvert To Hex = True<br \/>\nBaud Rate = 4800<br \/>\nParity = None<br \/>\nStop Bits = 2<br \/>\nData Bits = 8<br \/>\nPower Option = RTS<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Rig Interface Help Aide de l&rsquo;interface de rig Voici les informations essentielles dont vous aurez besoin pour connecter votre interface de plate-forme et de faire fonctionner avec AC Log et mon logiciel de concours. Pour commencer avec l&rsquo;interface de rig, vous aurez besoin du mat\u00e9riel d&rsquo;interface n\u00e9cessaire pour connecter votre rig \u00e0 votre PC. De &hellip; <a href=\"http:\/\/www.on4cn.be\/blog_radio\/rig-interface\/\" class=\"more-link\">Continuer la lecture<span class=\"screen-reader-text\"> de &laquo;&nbsp;Rig Interface&nbsp;&raquo;<\/span><\/a><\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"onecolumn-page.php","meta":{"footnotes":""},"class_list":["post-11531","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"http:\/\/www.on4cn.be\/blog_radio\/wp-json\/wp\/v2\/pages\/11531","targetHints":{"allow":["GET"]}}],"collection":[{"href":"http:\/\/www.on4cn.be\/blog_radio\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"http:\/\/www.on4cn.be\/blog_radio\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"http:\/\/www.on4cn.be\/blog_radio\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"http:\/\/www.on4cn.be\/blog_radio\/wp-json\/wp\/v2\/comments?post=11531"}],"version-history":[{"count":0,"href":"http:\/\/www.on4cn.be\/blog_radio\/wp-json\/wp\/v2\/pages\/11531\/revisions"}],"wp:attachment":[{"href":"http:\/\/www.on4cn.be\/blog_radio\/wp-json\/wp\/v2\/media?parent=11531"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}